CONDO FRESH

Catagory : Filter Housings
CONDO FRESH
FRESH AIR INTAKE FILTER HOUSINGS | CASINGS
Fresh Air Single, Multiple Stage Filtration Systems with Coarse and Fine Filtration application in all end user Applications.
PRODUCT SPECIFICATIONS | ||
---|---|---|
Category | Modular Design single/multi-stage filter Housings | |
Housing Box material | 1. Single Skin-Galvanized steel/Mild Steel with Powder Coated Finish / Stainless Steel 2. Double Skin sandwich Panels with PUF insulation. The inner & outer sheets are epoxy coated Galvanized steel. The Double skin panel is arranged with extruded aluminum profile for modularity. The Housings are weatherproof for outside installation. | |
Door Hatch | 1.Side access Hinged Door hatch provided on either Left or right side of housing with locking handles, for filter installation. 2.Removable door with fire rated plastic knobs can be provided(optional) | |
Filter Tracks | Galvanized steel / Aluminum/Stainless Steel | |
Differential Pressure Monitoring | Individual Pressure Gauge or DP switch for each filter stage with hose connectors are provided. | |
Base Frame/Hanging Taps(optional) | Base frame with Lifting lugs or Hanging Taps can be provided | |
Flanges | Pre-drilled flanges provided on both sides of housing to connect to other HVAC equipment | |
Gaskets | Continuous gasket for tight sealing of door to filter housing. | |
Fan (Optional) | Internal Fan can be provided for supply or extract application. | |
Filter Stages | First Stage- Pre-Filter such as Aluneta/Superwash Second Stage- Fine Filter such as Synpak/Glasspak Third Stage- Super fine Filter such as Vpak/Zpak *Wide range of sizes and combination of filter banks available. *For filter selection, refer technical catalogue of filters. | |
Fan (Optional) | Internal Fan can be provided for supply or extract application. | |
Airflow | A full module filter can handle 2000 CFM (24”x 24”) Contact factory for customized designs. Refer relevant page of catalogue for information on Design | |
Standards | Complies with EN 15805, ISO 16890, ASHRAE 52.2, EN779, EN 1822 & NAFA design standards |
APPLICATIONS
- Kitchen Make up air unit
- Commercial buildings
- Industrial applications
- Health Care Facilities
- Airports
- Biomedical
- Pharmaceutical
- Universities
- Laboratories
- Hospitals
- Clean Rooms
- Food processing plants
- Museums
- Offices
- Public buildings
Features & Advantages
- The CONDO FRESH filter housings are standardized filter casings, designed to fit all Apter Technology Coarse and fine filters for creating a total clean air solution.
- The Fresh air housings are used where high purity fresh is required and special areas such as kitchen make up air units, factories, laboratories, Hospitals, Pharmaceutical firms
- The Housings are leak proof constructed with a stable and secured design.
- The Housings can easily be mounted between the ducts.
- The Modular design provides seamless integration with a variety of HVAC equipment and operational environments.
- The Condos are easy to handle and install at site.
- No separate tools are needed to install and replace the filters
- The housing walls can be Single skin or Double walled insulated construction (for heat insulation and to prevent condensation). The Galvanized steel / Mild steel/ Stainless steel housings provide excellent strength and rigidity.
- Side access door provided for filter installation, inspection and maintenance.
- The filters are installed by sliding into the filter tracks or channels provided in housing
- The filters are held in place by robust clamping mechanisms which ensures tight sealing and prevents chance of air leakage.
- Separate Air tight clamping designs can be incorporated for leak proof filter installation- (For HEPA filters).
- Seamless gasket provided at inside of the service door makes the housing airtight
- Dual access door can be provided for bigger housings to handle large air volumes with maximum up to Five filters wide and Four filter high configurations.
- Housing is all weatherproof for outside installation
- Base frame with Lifting lugs or Hanging taps can be provided upon request
- Wide range of sizes and combination of filter banks are available
- Filters are selected based on Application, Efficiency requirements, airflow, pressure drop, velocity, type of contaminant to be arrested, contaminant concentration.
- Technical Drawings shall be provided during the production process for client approval.