HEPA DUCTED LAMINAR FLOW TERMINAL MODULE | CASINGS
Laminar Flow Terminal Housing Box with Gel seal type or Gasket type HEPA filters for No Air-bypass construction for critical Applications.
PRODUCT SPECIFICATIONS | ||
---|---|---|
Category | Terminal HEPA Module-Replaceable HEPA type | |
Housing Box material | Galvanized steel or Mild Steel-Powder Coated /Stainless steel. Fully welded joints & Seams | |
Finish | RAL finish in various grade/epoxy coated-to prevent corrosion | |
Diffuser / Face Guard | Removable flush type with SS nuts or Hinged type. Type-Perforated/Swirl/adjustable vane/4-way diffusers | |
Spigot connection | Top inlet or Side inlet | |
Spigot | Ribbed circular spigot or square inlet connection on top. Inlet connections are continuously welded. | |
Air Distribution Plate (Optional) | Located at plenum inlet collar for uniform air distribution over filter air entry side. Plate made from SS/MS | |
Filter Installation & Mounting | Easily installed from room side by removing diffuser. Filter locking using quarter turn locks or quick clamping mechanisms with gasket compression inbuilt. | |
Volume Control Damper (Optional) | Provided at spigot side for controlling airflow. Damper is room side adjustable or adjustable from ceiling side | |
Pressure Measurement port cum Aerosol Measurement (optional) | Measure filter replacement pressure drop at site & for upstream aerosol measurement | |
Aerosol Injection system (Optional) | Separate port for Aerosol injection from room side | |
Damper Control system (Optional) | Damper Operated from Room side by mechanical rod linkage | |
Aerosol Dispersion system (optional) | For even dispersion of aerosol over filter face area | |
Pressure Monitoring | DP switch for signaling filter replacement | |
Hanging Tabs | Fully welded hanging tabs used for ceiling suspension. 10mm Ø hole is provided for hanging. | |
Housing Box Insulation (Option) | Foil backed insulation-2” thick | |
Terminal Box Height | Standard height is 12”. Other Box height based on filter depths | |
Performance Testing | Each terminal module shall be fully leak tested. All welds and penetrations shall be bubble tested for leaks and must meet zero leak criteria. | |
Pre-Filter (Optional) | Additional chamber for Pre-Filter installation can be provided | |
HEPA Filter | Seamless PU Gasket type or Gel Seal type. Please refer Hepa filter technical catalogue for selection. | |
HEPA Grade as per EN 1822 | H13/H14/U15 | |
Maximum Pressure drop of filter | 450 Pa |
APPLICATIONS
- Final filtration in Clean Rooms
- Health Care Facilities
- Biomedical
- Pharmaceutical
- Universities
- Laboratories
- Hospitals
- Operation Theatre
- Food processing plants
- Microelectronics
Features & Advantages
- The CONDO Pharma modules is used in critical areas where highest degree of air cleanliness is required and can provide both laminar flow as well as turbulent airflow in Clean Rooms.
- These Terminal modules are used as final filtration in room ceiling side and for laminar flow applications such as in Hospitals, Pharmaceutical industry, Biomedical facilities, laboratories, microelectronics industry, food processing industry
- Circular spigot diameter shall be 200mm/250mm/300mm as per airflow requirements
- Square or rectangular top or side spigot will have flanges for connection to duct work
- The hood shall have channel to fix the HEPA filter. In case of Gel seal HEPA filter, integral knife edge shall be provided.
- The Diffuser plate shall be easily removable for filter replacement. The diffuser shall have hemmed edges. Other than perforated flat type diffuser other options include Swirl type, adjustable vane type or 4-way diffusers.
- Damper can be provided at air inlet side for controlling the airflow. The damper can be adjustable from room side or ceiling side adjustable.
- A wide range of HEPA filter choices based on airflow handling capacity and pressure drop criteria can be opted for.
- The HEPA filters are tested and certified as per EN 1822 and complies to ISO 14644 standard of testing.
- Filters are selected based on airflow, efficiency and pressure drop requirements.
- All the hoods shall be fully leak tested, visually inspected and tested as per the standards for the Zero leak performance.
- In house test certificates are provided for HEPA filter and housing Box certifying its leak proof performance.