CONDO TERMI

Catagory : Filter Housings
CONDO TERMI
ROOM SIDE REPLACEABLE TERMINAL MODULES | CASINGS
Room Side Replaceable Terminal Side Laminar Flow Housings for Hospital / Pharma / Cleanroom application with diffusers.
PRODUCT SPECIFICATIONS | ||
---|---|---|
Category | Terminal HEPA Module-Ready to install type | |
Housing Box material | Anodized and Extruded Aluminum Profile | |
Top Cover | Galvanized steel cover | |
Gasket | No gasket at outlet side | |
HEPA Filter | Gel Seal HEPA Filter | |
Media | Micro Glass fiber | |
Media Separator | Hot melt glue | |
Filter-frame to media sealing | 2 component Polyurethane glue | |
Spigot | spigot Diameter of 250 mm/300mm depending on the airflow. The spigot is connected to flexible duct connector. The spigot height is 50 mm-100 mm. | |
Air Distribution Plate | Perforated Aluminum, screw adjustable distribution plate- Located at the plenum inlet collar for uniform air distribution | |
Face guard/ Diffuser | Perforated stainless steel or G.I Powder coated diffuser with hemmed edges | |
Hanging Tabs | Built in Seismic holes are used for ceiling suspension (10mm Ø hole) | |
Test Port | Provided at filter central partition & accessible from room side by removing diffuser. Used for measuring filter replacement pressure drop | |
HEPA Grade as per EN 1822 | H13/H14/U15 | |
Recommended final pressure drop | 500 Pa | |
Maximum Temperature | 75º C | |
Maximum Relative Humidity | 90% | |
Filter installation & replacement | Room side replaceable filter by removing the diffuser plate. Channels provided to fix HEPA Filter & a fastening system clamps the HEPA filter inside the Box. | |
Performance Testing | Each terminal module shall be fully leak tested. |
APPLICATIONS
- Final filtration in Clean Rooms
- Health Care Facilities
- Biomedical
- Pharmaceutical
- Universities
- Laboratories
- Hospitals
- Operation Theatre
- Food processing plants
- Microelectronics
Features & Advantages
- The CONDO Termi ready to install modules is used in critical areas where highest degree of air cleanliness and where highest filtration efficiency is specified.
- These Terminal modules are used as final filtration in room ceiling side and laminar flow applications such as in Hospitals, Pharmaceutical industry, Biomedical facilities, laboratories, microelectronics industry, food processing industry
- The HEPA filters are tested and certified as per EN 1822 and complies to ISO 14644 standard of testing.
- In house test certificates are provided for HEPA filter and housing Box.
- The housings are light weight and leak proof in construction.
- The low pressure drop design of filter reduces energy consumption and filters are selected based on airflow, efficiency and pressure drop requirements.
- All the hoods shall be visually inspected and tested as per the standards for the leak proof performance
- The Diffuser shall clamp with the Hood by Stainless steel screws.
- The unit produces low noise-35dB at recommended velocity